( Brand: Amscope ), ( Manufacturer Part Number: DK-SET-670-IRIS ), ( Part Type: Condenser ), ( UPC: 840979120916 )
Experience the captivating world of microscopy like never before with the DK-SET-670 Iris Amscope Darkfield Condenser Objective Set. This comprehensive accessory kit, specifically designed for 670 series microscopes, offers a versatile and high-performance solution for your observation needs, catalog number 840979120916.
The set includes a meticulously crafted series of darkfield condenser and objective lenses. These lenses are engineered to deliver exceptional image clarity, contrast, and resolution, making them ideal for a wide range of applications, from educational settings to professional research.
The DK-SET-670 features an iris diaphragm, which provides precise control over the light intensity and focus, ensuring that even the subtlest details are brought to light. The darkfield condenser, on the other hand, is designed to project light around the sample, creating stunning contrast and revealing intricate structures that would otherwise go unnoticed.
This set includes the following lenses: 4x, 10x, 20x, and 40x objectives, and a 0.65x darkfield condenser. Each lens is coated with Amscope's proprietary multi-layer coating, enhancing light transmission and reducing unwanted reflections, thereby improving the overall image quality.
The DK-SET-670 Iris Amscope Darkfield Condenser Objective Set is a must-have accessory for any microscopy enthusiast or professional. With its exceptional quality, versatility, and ease of use, it will undoubtedly elevate your microscopic explorations to new heights. Invest in this set today, and unlock a world of discovery that awaits you under the microscope.
The Amscope DK-Set-670-IRIS Darkfield Condenser Objective Set (670 microscopes, part number 840979120916) is a darkfield condenser and objective set designed for use with microscopes. Here are some pros and cons to consider before making a purchase:
Pros:1. Darkfield illumination: This condenser set is specifically designed for darkfield microscopy, allowing you to observe objects against a dark background, which can help enhance the contrast and reveal details that might be missed in brightfield microscopy.
2. High-quality optics: The set includes objective lenses with high-quality glass, ensuring clear and sharp images.
3. IRIS diaphragm: The condenser features an adjustable diaphragm, which allows for precise control of the illumination, helping to reduce flare and improve contrast.
4. Compatibility: This set is compatible with various Amscope microscopes, making it a versatile option for those who already own an Amscope microscope or are considering purchasing one.
5. Affordable: Compared to some other darkfield condenser sets, this one is relatively affordable, making it an attractive option for hobbyists and professionals on a budget.
Cons:1. Limited magnification range: The objective lenses included in this set offer a relatively limited range of magnification, which may not be suitable for all applications.
2. No phase contrast: This set does not include a phase contrast condenser, which may be a disadvantage for those who require phase contrast microscopy.
3. Compatibility issues: While the set is compatible with various Amscope microscopes, it may not be compatible with microscopes from other manufacturers, so it's important to verify compatibility before making a purchase.
4. Potential learning curve: Darkfield microscopy can be more challenging to learn than brightfield microscopy, and it may require some practice to get the hang of it.
Conclusion:The Amscope DK-Set-670-IRIS Darkfield Condenser Objective Set is a high-quality, affordable option for those interested in darkfield microscopy. Its adjustable diaphragm, high-quality optics, and compatibility with various Amscope microscopes make it a versatile choice for hobbyists and professionals. However, its limited magnification range and lack of phase contrast condenser may be disadvantages for some users. Ultimately, the decision to purchase this set will depend on your specific needs and the type of microscopy you plan to perform.
Condenser specifications: mount: front-loading with flange mounting diameter: 37mm compatibility: 670 series compound microscopes numerical aperture. 36 oil immersion medium: none dry, objective specifications: infinity-corrected plan achromatic with iris magnification: 100x numerical aperture: 0.
Items damaged in transit are not covered by us.
Come with a one 1 year warranty.
The 100x lens built-in iris-control allows Na to be fine-tuned for optimal results.
Warranty does not cover consumable accessories and parts such as bulbs. One year warranty for accessories - all our microscope USB cameras, illuminates, illumination, dust covers, and etc.
9 is best-suited for lower-magnification objectives, typically up to 40x. This is particularly useful for quantitative analysis of low-contrast specimens.
A variable-aperture 100x objective is also included, to better control contrast at the highest magnification.
As well, the oil condenser will produce brighter highlights. Darkfield microscopy uses principles of light-diffraction to suppress field-illumination, while illuminating the edges otherwise-transparent or translucent objects through use oblique light. Warranty service times vary throughout the year, and are processed in a first come, serve manner, when parts available stock.
Note: buyers bear the cost of shipping and handling round trip for warranty services. Both dry and oil condensers are included to cover a wide range of magnifications numerical apertures.
9 dry, Processing is done first come, serve, and can take between 1-4 weeks to process depending on how many requests we currently have in queue.
Five year warranty for microscopes - all our come with a 5 factory against manufacturing defects, covering labor and parts. Warranty information we, Amscope, provide all services.
The dry condenser, with an Na of. Note that shipping costs are borne by the customer.
36, and is necessary for higher-magnification objectives. The oil condenser has a maximum Na of Because darkfield uses oblique light explicitly, an objective lens numerical aperture must be significantly lower than that of the condenser to optimize contrast.